Steam and water exchangers
These devices heat a fluid, typically methane, by means of thermal exchange between steam and gas (
steam exchangers) or water and gas (
water exchangers).
HEATER EXCHANGERS OF HIGH PRESSURE according to “PED” DIRECTIVES SC / 0.5– SC / 1 – SC / 2 – SC / 3 – SC / 4 SC/5
|
Vista dall'alto |
|
|
NOTES:
- The outlet on the top of the water jacket is 3/8"
- On the water jacket a drain valve of 1/2" F-F is supplied
- The drainages on gas side are couplings of 1/2" 3000 NPT. The exchanger is provided with plugs of 1/2"3000 NPT
CHART OF "SIZES AND OVERALL DIMENSIONS"
TYPE
|
Ø
|
DN GAS SIDE N1-N2
|
Z
|
X
|
Y
|
S
|
H
|
I
|
Gas Side Capacity
|
Water side Capacity
|
Weight (Kg)
|
Power (Kcal/ h)
|
M2 exchanging surface
|
SC / 0.5
|
141.3
|
25 – 50
|
1820
|
950
|
330
|
180
|
800
|
500
|
3
|
15
|
90
|
14500
|
0,64
|
SC / 1
|
168.3
|
40 – 65
|
2329
|
950
|
390
|
200
|
800
|
550
|
11
|
23
|
150
|
26800
|
1,2
|
SC / 2
|
219.1
|
50 – 100
|
2440
|
975
|
420
|
220
|
800
|
600
|
23.5
|
30
|
255
|
64500
|
2,04
|
SC / 3
|
273
|
80 – 150
|
2627
|
1100
|
460
|
300
|
800
|
800
|
45
|
50
|
320
|
100000
|
3,5
|
SC / 4
|
323.8
|
100 –200
|
2652
|
1100
|
500
|
325
|
800
|
800
|
68
|
80
|
570
|
165000
|
5,5
|
SC / 5
|
406.4
|
125 –250
|
3050
|
1100
|
550
|
350
|
800
|
1000
|
127
|
127
|
700
|
250000
|
11,5
|
|
|